站内搜索
|
详细信息 Product Name: Medical Hospital High Frequency 500mA 50kw X-ray Machine Model NO.: Xrx-HFMB500 Group: All People Certification: CE, MSDS, ISO13485 Type: X Ray Equipment Classification: Imaging Diagnostic Equipment Output Power: 40kw Radiography Tube Current: 10-500mA Power Supply: 220V, 50kHz Inverter Frequency: 50kHz Radiography Tube Voltage: 40-150kv Battery: Available Lithium Touch Screen: Available Operation Method: Wire/ Wireless Control After-Sales Service: Whole Using Lifetime Trademark: XINDRAY MEDICAL Transport Package: Wooden Case Specification: 650cm*300cm*190cm Origin: China Product Description Medical Hospital High Frequency 500mA 50kw X-ray MachineFeatures:1. With high frequency inverter to emit high quality X-ray and low dose on skin, and ensure excellent definition and contrast of pictures.2. With techniques of KV analog closed loop control, mAs digital closed loop control and micro-processing real-time control to ensure precision and repeatability of the dose.3. With kV, mAs two button adjustment, LCD display, multifunction of safety guard.4. With 50 preset exposure programs, and can be modified and stored by the user for convenient operation.5. With a high-quality knockdown X-ray generator to reduce irradiation, which is much safer to environment and operator.6. With a symmetrical beam applicator to adjust the X-ray field and a collimator lamp to locate the filed to ensure accurate radiograph.Specifications:Item Specification1.X- ray High voltage generator1.1Standard output power:40kW 1.2mA range:10-500mA1.3Tube voltage range:40-150kV1.4mAs range :0.1-250mAs1.5Load time range:0.001s~6.3s1.6Input voltage:450VDC/48VDC±10%1.7High voltage output master frequency:50kHz±5%1.8High voltage transformer structure:The power frequency2.X-ray tube 2.1Focus range:0.6/1.2mm2.2Anode heat capacity :150kHu2.3Anode types: rotating anode, maximum speed: 3200 revolutions per minute2.4Pipe sleeve heat capacity: 1250kHu2.4The maximum voltage:150kV2.5The anode input power:Big focus:50kW ,Small focus:22kW2.6Anode angle 12°2.7The inherent filtration:1.3mm Al/75kV3. Collimator3.1The inherent filtration:1.0 mm Al /75 kV;3.2Collimatoris equipped with LED lights(Bright 30s are automatically extinguished)3.3Collimator is built into measuring ruler4. The tube bracket structure4.1X-ray tube support way: Folding arm4.2Tube focus distance to the ground:507mm~2000mm,±5%4.3Arm's Folding Range :±60°4.4Tube Tilting Angle:±90°4.5Tube Vertical Rotation Angle:-30°~+90°4.6Collimator axial rotation :±360°5. Detector 5.1WIFI connection ,Amorphous Silicon ,whole panel technology 5.2Detector valid exposure size :350×430mm5.3Pixel size:150 µm5.4The effective camera size of the detector:14×17inch5.5Gathering matrix:≥2304×2800pixels;5.6Spatial resolution≥3.4lp/mm5.7Pixel gray level:≥14bit5.8Detector cooling mode: natural cooling6. Digital image workstation6.1CPU frequency:CORE i36.2Memory capacity:4GB6.3Hard drive capacity :500 GB6.4Display size: 17 inch LCD touch screen6.5Display screen Maximum resolution≥1280×1024;6.664 bit Windows operation system7. Image acquisition software7.1Patient registration: acquisition, find the patient data, to prepare for the photography7.2Radio graphic examination:setting system parameters, exposure photography and get the image7.3Images display, image analysis, processing and output7.4Data management: managing patient data, leading in, leading out , batch file, etc in accordance with DICOM3.07.5Configure calibration: the system components such as flat-panel detector, such as tube for automatic configuration and calibration7.6System diagnosis: monitoring system status, diagnosis of the system fault7.7Image Printing: Image Output to Film Printer8. Battery8.1Power supply way8.1.1Lithium battery power supply8.1.2The rated capacity:46.8V,10.8Ah(Lithium battery meets UN38.3 standard requirements)8.1.3Battery capacity: More than200exposures, chest image dosage (exposure conditions: 120 kv, 100 mA, 20ms )8.2Dual power supply, exposure under either wall current or lithium battery8.3Maximum charging 4 hours8.4Can support hand switch and remote control 9. The machine parameters9.1Appearance size:1560mm×650 mm×1490mm9.2Whole weight (no detector):220kg10.External interface10.1Display interface(DVI)10.2Wireless network data transmission(WIFI)10.3Cable network interface10.4USB(2)11.Options11.1Chest rack11.2Moving flat bedCertificate:Package:Shipping:Our Service:
|